Electonic circuits and schematics
Google
  Electronic circuits schematics Home Search Most popular Sitemap  
Search circuits



Categories

Circuits & schematics

  • Audio
  • Automotive
  • Games and entertainment
  • Microcontrollers
  • Miscellaneous
  • Models and model remote control
  • Motor, light and power control
  • Oscillators and timers
  • PC related
  • Power
  • RF circuit
  • Robotics
  • Security and other sensors and detectors
  • Telephone related
  • Test and measurement
  • Video and TV
  • Electronics guide

  • The very first steps
  • On the boards
  • Measuring current and voltage
  • Capacitors
  • ICs, oscillators and filters
  • Diodes I
  • Diodes II
  • Transistors
  • Analogue integrated circuits
  • Digital integrated circuits I
  • Digital integrated circuits II

  • Electronic circuits and electronic schematics


    Schematics > Audio > Precision Audio Millivoltmeter

    Precision Audio Millivoltmeter

    Measures 10mV to 50Volt RMS in eight ranges

    Simply connect to your Avo-meter set @ 50µA range

    Audio Millivoltmeter



    Parts:

    R1_____909K 1/2Watt 1% Metal Oxide Resistor
    R2______90K9 1/2Watt 1% Metal Oxide Resistor
    R3_______9K09 1/2Watt 1% Metal Oxide Resistor
    R4_______1K01 1/2Watt 1% Metal Oxide Resistor
    R5_____100K 1/4W Resistor
    R6_______2M2 1/4W Resistor
    R7______82K 1/4W Resistor
    R8______12K 1/4W Resistor
    R9_______1K2 1/4W Resistor
    R10______3K3 1/4W Resistor
    R11____200R 1/2W Trimmer Cermet

    C1_____330nF 63V Polyester Capacitor
    C2,C3__100µF 25V Electrolytic Capacitor
    C4_____220µF 25V Electrolytic Capacitor
    C5______33pF 63V Polystyrene Capacitor
    C6_______2µ2 63V Electrolytic Capacitor

    D1-D4___1N4148 75V 150mA Diodes

    IC1_____CA3140 Op-amp
    IC2_____CA3130 Op-amp

    SW1_____2 poles 5 ways rotary switch
    SW2_____SPDT switch

    J1______RCA audio input socket
    J2,J3___4mm. output sockets

    B1______9V PP3 Battery

    Clip for PP3 Battery

    Notes:

    • Connect J2 and J3 to an Avo-meter set @ 50µA range
    • Switching SW2 the four input ranges can be multiplied by 5
    • Total fsd ranges are: 10mV, 50mV, 100mV, 500mV, 1V, 5V, 10V, 50V
    • Set R11 to read 1V in the 1V range, with a sinewave input of 1V @ 1KHz
    • Compare the reading with that of another known precision Millivoltmeter or with an oscilloscope
    • The oscilloscope reading must be a sinewave of 2.828V peak to peak amplitude
    • Frequency response is flat in the 20Hz-20KHz range
    • If you have difficulties in finding resistor values for R1, R2, R3 & R4, you can use the following trick:
      R1 = 10M + 1M in parallel
      R2 = 1M + 100K in parallel
      R3 = 100K + 10K in parallel
      R4 = 1K2 + 6K8 in parallel
      All resistors 1% tolerance

    Title: Precision Audio Millivoltmeter
    Source: www.redcircuits.com
    Published on: 2005-02-01
    Reads: 396
    Print version: Print version

    Other schematics from Audio
  • Mini-box 2W Amplifier
  • Amplifier 2x30W with STK465
  • Stereo Preamplifier with Bass-boost
  • Ultrasonic pest repellent
  • Portable Microphone Preamplifier
  • 1W Bass Power Amplifier
  • Stereo Channel Selector
  • Electret Microphone Pre-Amplifier
  • Two way cross-over 3500 Hz
  • Simple Intercom

  • Schematics > Audio > Precision Audio Millivoltmeter


    реферат - subtitles - реферат - схеми - курсова робота - Творець галицьких залізниць - tools
    Page generation 0.014 seconds
    Precision Audio Millivoltmeter