Schematics > Test and measurement > Linear Resistance Meter
Linear Resistance MeterMost analogue multimeters are capable of measuring resistance over quite a
wide range of values, but are rather inconvenient in use due to the reverse
reading scale which is also non-linear. This can also give poor accuracy due to
cramping of the scale that occurs at the high value end of each range. This
resistance meter has 5 ranges and it has a forward reading linear scale on each
range.The full-scale values of the 5 ranges are 1K, 10K, 100K, 1M &10M
respectively and the unit is therefore capable of reasonably accurate
measurements from a few tens of ohms to ten Megohms.

The Circuit
Most linear scale resistance meters including the present
design, work on the principle that if a resistance is fed from a constant
current source the voltage developed across that resistance is proportional to
its value. For example, if a 1K resistor is fed from a 1 mA current source from
Ohm’s Law it can be calculated that 1 volt will be developed across the resistor
(1000 Ohms divided by 0.001 amps = 1 volt). Using the same current and
resistance values of 100 ohms and 10K gives voltages of 0.1volts (100 ohms /
0.001amps = 0.1volts) and 10 volts (10000 ohms / 0.001amps = 10 volts).
Thus the voltage developed across the resistor is indeed
proportional to its value, and a voltmeter used to measure this voltage can in
fact be calibrated in resistance, and will have the desired forward reading
linear scale. One slight complication is that the voltmeter must not take a
significant current or this will alter the current fed to the test resistor and
impair linearity. It is therefore necessary to use a high impedance voltmeter
circuit.
The full circuit diagram of the Linear Resistance Meter is
given in Figure 1. The constant current generator is based on IC1a and Q1. R1,
D1 and D2 form a simple form a simple voltage regulator circuit, which feeds a
potential of just over 1.2 volts to the non-inverting input of IC1a. There is
100% negative feedback from the emitter of Q1 to the inverting input of IC1a so
that Q1’s emitter is stabilised at the same potential as IC1a’s non-inverting
input. In other words it is stabilised a little over 1.2 volts below the
positive supply rail potential. S3a gives 5 switched emitter resistances for Q1,
and therefore 5 switched emitter currents. S3b provides 5 reference resistors
across T1 & T2 via S2 to set full-scale deflection on each range using VR1.
As the emitter and collector currents of a high gain
transistor such as a BC179 device used in the Q1 are virtually identical, this
also gives 5 switched collector currents. By having 5 output currents, and the
current reduced by a factor of 10 each time S3a is moved one step in a clockwise
direction, the 5 required measuring ranges are obtained. R2 to R6 must be close
tolerance types to ensure good accuracy on all ranges. The high impedance
voltmeter section uses IC1b with 100% negative feedback from the output to the
inverting input so that there is unity voltage gain from the non-inverting input
to the output. The output of IC1b drives a simple voltmeter circuit using VR1
and M1, and the former is adjusted to give the correct full-scale resistance
values.
The CA3240E device used for IC1 is a dual op-amp having a
MOS input stage and a class A output stage. These enable the device to operate
with the inputs and outputs right down to the negative supply rail voltage. This
is a very helpful feature in many circuits, including the present one as it
enables a single supply rail to be used where a dual balanced supply would
otherwise be needed. In many applications the negative supply is needed simply
in order to permit the output of the op-amp to reach the 0volt rail. In
applications of this type the CA3240E device normally enables the negative
supply to be dispensed with.
As the CA3240E has a MOS input stage for each section the
input impedance is very high (about 1.5 million Megohms!) and obviously no
significant input current flows into the device. This, together with the high
quality of the constant current source, and the practically non-existent
distortion through IC1b due to the high feedback level gives this circuit
excellent linearity.
With no resistor connected across T1 & T2 M1 will be taken
beyond full-scale deflection and overloaded by about 100 or 200%. This is
unlikely to damage the meter, but to be on the safe side a push-to-test on/off
switch (S1) is used. Thus the power is only applied to the circuit when a test
resistor is connected to the unit, and prolonged meter overloads are thus
avoided.
A small (PP3 size) 9 volt battery is a suitable power
source for this project which has a current consumption of around 5mA and does
not require a stabilised supply.
Photos showing inside and outside of the completed Linear Resistance Meter.


Title: Linear Resistance Meter
Source: www.electronics-lab.com
Published on: 2005-02-10
Reads: 233
Print version:  Other schematics from Test and measurement Electronic Thermostat and Relay Circuit Contactless Mains Voltage Indicator Triangle / Squarewave Generator Digital Voltmeter Oscilloscope testing module (huntron circuit) Function Generator Voltage follower with 1G ohm input resistance Audio level meter (vumeter) 1GHz Simple Frequency Counter A simple Remote control Tester Schematics > Test and measurement > Linear Resistance Meter |